A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Hayes, T.

Paper Title Page
MOPLT159 RF Techniques for Improved Luminosity at RHIC 905
 
  • J.M. Brennan, M. Blaskiewicz, J. Butler, J. DeLong, W. Fischer, T. Hayes
    BNL, Upton, Long Island, New York
 
  The Relativistic Heavy Ion Collider has improved its luminosity performance significantly in the course of the first three physics runs. A number of special techniques for the operation of the rf systems have been developed to facilitate these improvements. Herein we describe these techniques, which include: an ultra low-noise rf source for the 197 MHz storage cavities; synchronization of the two rings during acceleration (including crossing the transition energy) to avoid spurious collisions on the ramp, which modulate the beam-beam tune shift; a frequency shift switch-on technique for transferring bunches from the acceleration to the storage rf systems; installation of dedicated 200 MHz cavities to provide longitudinal Landau damping on the ramp, and automated corrections to longitudinal injection parameters to minimize emittance growth.  
TUPKF079 A Low Noise RF Source for RHIC 1123
 
  • T. Hayes
    BNL, Upton, Long Island, New York
 
  The Relativistic Heavy Ion Collider requires a low noise rf source to ensure that beam lifetime during a store is not limited by the rf system. The beam is particularly sensitive to noise from power line harmonics. Additionally, the rf source must be flexible enough to handle the frequency jump required for rebucketing (transferring bunches from the acceleration to the storage rf systems). This paper will describe the design of a Direct Digital Synthesizer (DDS) based system that provides both the noise performance and the flexibility required.

Work performed under the auspices of the US Department of Energy

 
MOPLT165 Luminosity Increases in Gold-gold Operation in RHIC 917
 
  • W. Fischer, L. Ahrens, J. Alessi, M. Bai, D. Barton, J. Beebe-Wang, M. Blaskiewicz, J.M. Brennan, D. Bruno, J. Butler, R. Calaga, P. Cameron, R. Connolly, T. D'Ottavio, J. DeLong, K.A. Drees, W. Fu, G. Ganetis, J. Glenn, T. Hayes, P. He, H.-C. Hseuh, H. Huang, P. Ingrassia, U. Iriso, R. Lee, Y. Luo, W.W. MacKay, G. Marr, A. Marusic, R. Michnoff, C. Montag, J. Morris, T. Nicoletti, B. Oerter, C. Pearson, S. Peggs, A. Pendzick, F.C. Pilat, V. Ptitsyn, T. Roser, J. Sandberg, T. Satogata, C. Schultheiss, A. Sidi-Yekhlef, L. Smart, S. Tepikian, R. Tomas, D. Trbojevic, N. Tsoupas, J. Tuozzolo, J. Van Zeijts, K. Vetter, K. Yip, A. Zaltsman, S.Y. Zhang, W. Zhang
    BNL, Upton, Long Island, New York
 
  After an exploratory phase, during which a number of beam parameters were varied, the RHIC experiments now demand high luminosity to study heavy ion collisions in detail. Presently RHIC operates routinely above its design luminosity. In the first 4 weeks of its current operating period (Run-4) the machine has delivered more integrated luminosity that during the 14 weeks of the last gold-gold operating period (Run-2). We give an overview of the changes that increased the instantaneous luminosity and luminosity lifetime, raised the reliability, and improved the operational efficiency.