TUPLT140 Redesign of the ISIS Main Magnet Power Supply Storage Choke 1455
 
  • A.J. Kimber, J.W. Gray, A. Morris
    CCLRC/RAL/ISIS, Chilton, Didcot, Oxon
 
  The ISIS facility, based at the Rutherford Appleton Laboratory in the UK, provides intense pulsed neutron and muon beams for condensed matter studies. As part of the facilities upgrade and refurbishment program, the 1MJ storage choke which forms part of the main magnet power supply system, will be replaced with a number of smaller units. The present storage choke, which consists of a split secondary winding transformer, is incorporated into a series-parallel resonant circuit known as the 'white circuit'. This circuit ensures that each magnet receives identical currents, but is not subjected to excessive voltages. Although the storage choke is essentially a transformer, its secondary magnetising inductance is relatively low and a precisely defined value. This paper discusses the design and development of ten smaller units which will eventually replace the present equipment, and the testing of a one fifth scale model, which will be used to prove the technology.  
TUPLT144 Upgrade of the ISIS Main Magnet Power Supply 1467
 
  • S. West, J.W. Gray, A. Morris
    CCLRC/RAL/ISIS, Chilton, Didcot, Oxon
 
  ISIS, situated at the Rutherford Appleton Laboratory (RAL) is the world?s most powerful pulsed neutron source. At the heart of the ISIS accelerator is a proton synchrotron which uses a ring of magnets connected in series and configured as a ?White Circuit?. The magnets are connected in series with capacitor banks so that they form a resonant circuit with a fundamental frequency of 50 Hz. The circuit allows the magnets to be fed with an AC current superimposed on a DC current. The AC is currently provided by a 1MVA Motor-Alternator set and it is now proposed to replace this by a solid state UPS (Uninterruptible Power Supply) system. Tests on a smaller 80kVA unit have shown that it is possible to control the magnet current with a modified UPS system in such a way that both the frequency, phase and output voltage are under the direct influence of the control system. This paper discusses the issues surrounding the upgrading of AC supply to the main magnets with a view to improving the system reliability, improving magnet current stability and reducing the risk of mains failure.