  • Y. Funakoshi, K. Akai, K. Ebihara, K. Egawa, A. Enomoto, J. Flanagan, H. Fukuma, K.  Furukawa, T. Furuya, J. Haba, S. Hiramatsu, T. Ieiri, N. Iida, H. Ikeda, T. Kageyama, S. Kamada, T. Kamitani, S. Kato, M. Kikuchi, E. Kikutani, H. Koiso, M. Masuzawa, T. Mimashi, A. Morita, T. Nakamura, H. Nakayama, Y. Ogawa, K. Ohmi, Y. Ohnishi, N. Ohuchi, K. Oide, M. Shimada, S. Stanic, M. Suetake, Y. Suetsugu, T. Sugimura, T. Suwada, M. Tawada, M. Tejima, M. Tobiyama, S. Uehara, S. Uno, S.S. Win, N. Yamamoto, Y. Yamamoto, Y. Yano, K. Yokoyama, M. Yoshida, M. Yoshida, S.I. Yoshimoto
    KEK, Ibaraki
  • F. Zimmermann
    CERN, Geneva
 
  The KEKB B-Factory is an electron-positron double ring collider working at KEK. Its peak luminosity surpassed 1034 /cm2/sec in May 2003 for the first time in the history of colliders. In this report, we summarize the history of KEKB with an emphasis of recent progress.  
TUPKF035 RF System for Compact Medical Proton Synchrotron 1039
 
  • Z. Fang, K. Egawa, K. Endo, S. Yamanaka
    KEK, Ibaraki
  • Y. Cho, T. Fusato, T. Hirashima
    DKK, Kanagawa
 
  The rf system has been developed for the compact medical proton synchrotron. The rf system will be operated in pulse mode with the fundamental rf frequency sweeping from 1.6 to 15 MHz during the acceleration time of 5 ms. The required rf cavity voltage is a function of acceleration time too, with the voltage of fundamental varying from 13 to 6 kV. Besides, high order harmonics are also considered to apply to the rf system, and the cavity peak voltage varying from 20 to 9 kV during the acceleration time is expected. The performance of the rf system is being studied and will be presented.  
THPLT072 Magnet and RF Systems of Small Pulse Synchrotron for Radiotherapy 2658
 
  • K. Endo, K. Egawa, Z. Fang, S. Yamanaka
    KEK, Ibaraki
 
  To cure the malignant tumor it is desirable to equalize the treatment level to everybody anywhere he lives in. Proton and/or carbon-ion therapy are now considered as a powerful remedy as the radiation dose can be easily concentrated to the target volume by utilizing the Bragg?s peak. If a small medical accelerator is developed at a reasonable cost, it has a big potential to promote the advanced medical treatment with the accelerator in every place. This pulse synchrotron aims to reduce the size of the accelerator by generating the high magnetic field in a short time which leads to a compact ring of high field magnets. Acceleration time is only 5 msec by using the discharge current of a capacitor bank as large as 200 kA at peak, almost equivalent to half sinusoidal 50 Hz. Part of the discharge current is branched to excite the quadrupole magnets to assure the tracking between the dipole and quadrupole fields. Pulsed power technique is also adopted to drive the RF power tubes. Both magnet and RF systems have been developed and being extensively studied. Technological sides of both systems will be treated in details as well as the computational beam behaviors in this pulse synchrotron.