A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Dowell, D.

Paper Title Page
MOPKF079 The Linac Coherent Light Source Photo-Injector Overview and Some Design Details 500
 
  • D. Dowell, R. Akre, L.D. Bentson, P. Bolton, R.F. Boyce, R. Carr, J.E. Clendenin, S.M. Gierman, A. Gilevich, K. Kotturi, Z. Li, C. Limborg-Deprey, W. Linebarger, M. Ortega, J. Schmerge, P. Smith, L. Xiao
    SLAC, Menlo Park, California
 
  The Linac Coherent Light Source (LCLS)[*] is a SASE free electron laser using the last 1/3 of the SLAC two mile linac to produce 1.5 to 15 angstrom x-rays in a 100 meter long undulator. A new 135 MeV photo-injector will be built in an existing, off-axis vault at the 2/3 point of the main linac. The injector accelerator consists of a BNL/SLAC/UCLA s-band gun followed by two 3-meter long SLAC accelerator sections. The 5.6 MeV beam from the gun is matched into the first accelerator section and accelerated to 135 MeV before injection onto the main linac axis with a 35 degree bend [**]. Several modifications have been made to the rf gun, linac and beamline as well as the inclusion of several diagnostics have been incorporated into the injector design to achieve the required 1.2 micron projected emittance at a charge of 1 nC. In addition, a laser heater [***], will increase the uncorrelated energy spread to suppress coherent synchrotron radiation and longitudinal space charge instabilities in the main accelerator and bunch compressors [****]. The configuration and function of the major injector components will be described.

* Linac Coherent Light Source (LCLS) CDR No. SLAC-R-593 UC-414, 2002 ** C. Limborg et al., Proc. of the 2003 International FEL Conf *** R. Carr et al, Contrib. to these proceedings **** Z. Huang et al., Contrib. to these proceedings

 
MOPKF083 Inverse Free Electron Laser Heater for the LCLS 512
 
  • R. Carr, L.D. Bentson, P. Bolton, D. Dowell, P. Emma, A. Gilevich, Z. Huang, J.J. Welch, J. Wu
    SLAC, Menlo Park, California
 
  The LCLS Free Electron Laser employs an RF photocathode gun that yields a 1 nC charge bunch a few picoseconds long, which must be further compressed to yield the high current required for SASE gain. The very cold electron beam from the RF photocathode gun is quite sensitive to microbunching instabilities such as coherent synchrotron radiation (CSR) in the compressor chicanes and longitudinal space charge (LSC) in the linac. These effects can be Landau damped by adding energy spread to the electron bunch prior to compression. We propose to do this by interacting an infrared laser beam with the electron bunch in an undulator added to the LCLS gun-to-linac injector. The undulator is placed in a 4-bend chicane to allow the IR laser beam to propagate co-linearly with the e-beam while it oscillates in the undulator. The IR laser beam is derived from the photocathode gun laser. Simulations presented elsewhere in these proceedings show that the laser interaction damps the microbunching instabilities to a very great extent. This paper is a description of the implementation of the laser heater  
MOPKF086 Modifications of the LCLS Photoinjector Beamline 521
 
  • C. Limborg-Deprey, D. Dowell, S.M. Gierman
    SLAC, Menlo Park, California
 
  The LCLS Photoinjector beamline is now in the Design and Engineering stage. The fabrication and installation of this beamline is scheduled for the summer 2006. The Photoinjector will deliver 10 ps long electron bunches of 1nC with a normalized transverse emittance of less than 1 mm.mrad for 80% of the slices constituting the core of the bunch at 135 MeV. In this paper, we describe some modifications of the beamline: new exit energy, additional focusing, insertion of a laser heater. We also describe an alternate tuning which is based on a laser pulse of 20ps. The advantages and drawbacks of this long pulse tuning are reviewed. A comparison of sensitivity to field errors and misalignment between the long pulse tuning and the nominal tuning is given.  
MOPKF042 Status of the SPARC Project 399
 
  • M. Ferrario, D. Alesini, M. Bellaveglia, S. Bertolucci, M.E. Biagini, R. Boni, M. Boscolo, M. Castellano, A. Clozza, G. Di Pirro, A. Drago, A. Esposito, D. Filippetto, V. Fusco, A. Gallo, A. Ghigo, S. Guiducci, M. Incurvati, C. Ligi, F. Marcellini, L. Pellegrino, M.A. Preger, R. Ricci, C. Sanelli, M. Serio, F. Sgamma, B. Spataro, A. Stecchi, A. Stella, F. Tazzioli, C. Vaccarezza, M. Vescovi, C. Vicario
    INFN/LNF, Frascati (Roma)
  • F. Alessandria, A. Bacci, M. Mauri
    INFN/LASA, Segrate (MI)
  • I. Boscolo, F. Brogli, S. Cialdi, C. De Martinis, D. Giove, C. Maroli, V. Petrillo, M. Romé, L. Serafini
    INFN-Milano, Milano
  • L. Catani, E.C. Chiadroni, A. Cianchi, S. Tazzari
    Università di Roma II Tor Vergata, Roma
  • F. Ciocci, G. Dattoli, A. Doria, F. Flora, G.P. Gallerano, L. Giannessi, E. Giovenale, G. Messina, L. Mezi, P.L. Ottaviani, L. Picardi, M. Quattromini, A. Renieri, C. Ronsivalle
    ENEA C.R. Frascati, Frascati (Roma)
  • D. Dowell, P. Emma, C. Limborg-Deprey, D. Palmer
    SLAC, Menlo Park, California
  • D. Levi, M. Mattioli, G. Medici
    Università di Roma I La Sapienza, Roma
  • M.  Migliorati, A. Mostacci, L. Palumbo
    Rome University La Sapienza, Roma
  • P. Musumeci, J. Rosenzweig
    UCLA, Los Angeles, California
  • M. Nisoli, S. Stagira, S. de Silvestri
    Politecnico/Milano, Milano
 
  The aim of the SPARC project is to promote an R&D activity oriented to the development of a high brightness photoinjector to drive SASE-FEL experiments at 500 nm and higher harmonics generation. It has been proposed by a collaboration among ENEA-INFN-CNR-Universita‘ di Roma Tor Vergata-INFM-ST and funded by the Italian Government with a 3 year time schedule. The machine will be installed at LNF, inside an existing underground bunker. It is comprised of an rf gun driven by a Ti:Sa laser to produce 10-ps flat top pulses on the photocathode, injecting into three SLAC accelerating sections. We foresee conducting investigations on the emittance correction and on the rf compression techniques up to kA level. The SPARC photoinjector can be used also to investigate beam physics issues like surface-roughness-induced wake fields, bunch-length measurements in the sub-ps range, emittance degradation in magnetic compressors due to CSR. We present in this paper the status of the design activities of the injector and of the undulator. The first test on diagnostic prototypes and the first experimental achievements of the flat top laser pulse production are also discussed.