A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Dehning, B.

Paper Title Page
MOPLT005 An Improved Collimation System for the LHC 536
 
  • R.W. Assmann, O. Aberle, A. Bertarelli, H.-H. Braun, M. Brugger, L. Bruno, O.S. Brüning, S. Calatroni, E. Chiaveri, B. Dehning, A. Ferrari, B. Goddard, E.B. Holzer, J.-B. Jeanneret, J.M. Jimenez, V. Kain, M. Lamont, M. Mayer, E. Métral, R. Perret, S. Redaelli, T. Risselada, G. Robert-Demolaize, S. Roesler, F. Ruggiero, R. Schmidt, D. Schulte, P. Sievers, V. Vlachoudis, L. Vos, G. Vossenberg, J. Wenninger
    CERN, Geneva
  • I.L. Ajguirei, I. Baishev, I.L. Kurochkin
    IHEP Protvino, Protvino, Moscow Region
  • D. Kaltchev
    TRIUMF, Vancouver
  • H. Tsutsui
    SHI, Tokyo
 
  The LHC design parameters extend the maximum stored beam energy 2-3 orders of magnitude beyond present experience. The handling of the high-intensity LHC beams in a super-conducting environment requires a high-robustness collimation system with unprecedented cleaning efficiency. For gap closures down to 2mm no beam instabilities may be induced from the collimator impedance. A difficult trade-off between collimator robustness, cleaning efficiency and collimator impedance is encountered. The conflicting LHC requirements are resolved with a phased approach, relying on low Z collimators for maximum robustness and hybrid metallic collimators for maximum performance. Efficiency is further enhanced with an additional cleaning close to the insertion triplets. The machine layouts have been adapted to the new requirements. The LHC collimation hardware is presently under design and has entered into the prototyping and early testing phase. Plans for collimator tests with beam are presented.  
THPLT009 Comparative Transverse Distribution Measurements between the New SPS Rest Gas Ionisation Monitor and the Wire Scanner Monitors. 2475
 
  • C. Fischer, B. Dehning, J. Koopman, D. Kramer, F. Roncarolo
    CERN, Geneva
 
  During the past two years, a new Ionization Profile Monitor was installed and tested in the CERN SPS. In parallel modifications were made on various wire scanner monitors. The aim is to develop instruments performing reliable measurements of transverse beam distributions in the SPS and in the LHC, in order to control the stringent emittance preservation requirements. Measurements made with the two types of monitors were performed under various conditions of LHC type beams, ranging from a pilot bunch up to beams having in the SPS nominal distributions in bunch number, intensity and energy for injection into the LHC. The data provided by the two types of instruments are compared. In the case of discrepancies, an analysis of the possible reasons is made. The cures implemented and the improvements foreseen are discussed.  
THPLT011 Longitudinal Loss Distribution along the LHC 2481
 
  • E.B. Holzer, B. Dehning
    CERN, Geneva
 
  For the design and calibration of the LHC beam loss monitoring system it is essential to have good predictions of the expected longitudinal loss distributions. For this purpose a complete and detailed aperture model of one LHC sector was compiled and included with the tracking code MAD. The positions of all beam pipe bellows are included in the model as well. Therefore, it allows investigating the loss pattern due to misalignment effects, in addition to steady beam losses (beam halo, beam-beam and beam-rest gas interactions) and orbit errors. Loss maps of halo particles originating from the betatron cleaning insertion have been created for proton and ion beams. The distribution of particle losses along the beam pipe is folded with the result of GEANT simulations of the shower development through the magnets and cold masses. They link the loss of a beam particle on the aperture to particle fluencies outside of the cryostats, where the beam loss monitors will be installed. These simulations determine the positioning of the loss monitors, the longitudinal distance one detector has to cover to achieve the required resolution as well as all calibration factors for the individual detectors. The model also serves to identify hot spots, which can limit the performance of the LHC.  
THPLT012 Design of the Beam Loss Monitoring System for the LHC Ring 2484
 
  • E.B. Holzer, B. Dehning, E. Effinger, G. Ferioli, J.L. Gonzalez, E. Gschwendtner, G. Guaglio, M. Hodgson, V. Prieto, C. Zamantzas
    CERN, Geneva
 
  The beam loss monitoring (BLM) system of the LHC is one of the most critical elements for the protection of the LHC. It must prevent the super conducting magnets from quenches and the machine components from damages, caused by beam losses. It helps in the identification of the loss mechanism by measuring the loss pattern. Special detectors will be used for the setup and control of the collimators. Furthermore, it will be an important tool during machine setup and studies. The specification requirements of the BLM system include a very high reliability  
THPLT015 Accuracy of Profile Monitors and LHC Emittance Measurements 2493
 
  • F. Roncarolo, G. Arduini, B. Dehning, G. Ferioli, J. Koopman, D. Kramer
    CERN, Geneva
 
  The monitoring and controlling of the beam transverse emittance is essential to allow high luminosity performances in a collider operation. The profile monitors in the LHC injection chain are exploited to determine their precision. A fit strategy was developed to reduce the fitting procedure error and make it negligible compared to instrumentation errors. The method proved to be robust against non-Gaussian tails and can estimate the fraction of non-Gaussian distributed beam intensity. The procedure was applied to the 2003 SPS Wire Scanner measurements with different kind of LHC type beams. The reproducibility of the six available monitors was determined by choosing one as a reference and making synchronized measurements. Several instrumental errors were discovered and corrected to the one per cent level. The demanding small LHC transverse emittances were determined under different beam conditions in terms of intensity, bunch spacing and length in the PS Booster, PS and SPS.