A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

David, Ch.

Paper Title Page
THPLT025 Using Visible Synchrotron Radiation at the SLS Diagnostics Beamline 2523
 
  • V. Schlott, M. Dach, Ch. David, B. Kalantari, M. Pedrozzi, A. Streun
    PSI, Villigen
 
  A diagnostics beamline has been set-up at the BX05 bending magnet of the SLS storage ring. It is equipped with a standard bending magnet front end, including two photon beam position monitors (PBPM) for determination of photon beam angle and position as well as a pinhole array monitor for online monitoring of beam size. The visual part of the dipole radiation is transported to an optical lab, where the temporal profile of the storage ring bunches can be measured with a minimal time resolution of 2 ps using a dual sweep, synchrocan streak camera. Simultaneously, beam size and coupling can be measured at 1.8 keV radiation energy with a zome plate monitor overcoming diffraction limitations. This paper describes the beamline design and summarizes the first experimental results.