WEPKF012 LHC Dipole Axis, Spool Piece Alignment and Field Angle in Warm and Cold Conditions 1618
 
  • M. Coccoli, M. Buzio, J. Garcia Perez
    CERN, Geneva
 
  The installation and commissioning of the LHC dipoles requires the knowledge of the magnetic axis and of the spool piece corrector alignment at the operating conditions. The installation is based at present on the use of geometric information derived from mechanical measurements performed in warm conditions, with the assumption that the geometric and magnetic axis are coincident. Any discrepancies between mechanical and magnetic axis and unforeseen geometry variations from ambient to cold operating temperature can introuduce important uncertaintes in the prediction of the alignment at operational conditions. Such prediction is studied through correlations between measurements performed at room and liquid helium temperature. A statistic analysis of the measurement data available is presented showing uncertainties on the correctors alignment. They are compared with beam-based specifications of the positioning of the spool piece.