A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z    

Botha, A.H.

Paper Title Page
THPLT047 Beam Position Monitor Development for the IThemba LABS Cyclotron Beamlines 2586
 
  • J. Dietrich, I. Mohos
    FZJ/IKP, Jülich
  • A.H. Botha, J.L. Conradie, J.L.G. Delsink, P.F. Rohwer
    IThemba Labs, Somerset West
 
  In cooperation of iThemba LABS (South Africa) and Forschungszentrum Juelich the specification of a sensitive tunable rf narrowband beam position monitor system for cyclotron beamlines has been elaborated. iThemba LABS developed and manufactured the four section stripline monitor chamber. The monitor electronics were developed in the Forschungszentrum Juelich-IKP. The electronics consisting of an RF signal processing module (BPM-RF) and a data acquisition and control module (BPM-DAQ) sequentially processes and measures the monitor signals and deliver via serial network calculated horizontal and vertical beam position data. First measurements with cyclotron beam has been performed in the iThemba LABS in November 2003. Changed beam position due to changing different cyclotron parameters could be studied with high accuracy. The resolution of the beam position measurement was better than 0.1 mm with beam currents down to 0.0005 mA.