THPME141 Design of Beam Intensity Measurement System in Injector for HLS II 3581
 
  • C. Cheng, P. Lu, B.G. Sun, K. Tang, J. Xu, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A new beam intensity measurement (BIM) system has been developed and has been used in the upgrade project of HLS II. After the upgrading is accomplished, electron energy in Injector endpoint will increase from 200MeV to 800MeV to achieve the goal of top-off injector. Meanwhile, macro pulse width changes from 1us to 1ns and peak intensity from 50mA to 1A approximately. So three fast current transformers (FCTs) and two integrating current transformer (ICTs) are installed in Linac and Transport Line to measure single pass beam parameters. In this article, off-line calibration of beam transformer is elaborated. Since the fast pulse signals from beam transformer will be hugely distorted after they transmit from Injector vacuum chamber to the Injector beam diagnostic centre room after hundreds of meters long LMR-400 cable, signal recovery algorithm based on FFT/IFFT is used to re-appear the true original signal and calculate the calibration efficient. In the end, resolution and measurement result of the BIM system is presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME141  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME143 Measuring Energy Spread Using Beam Screen Monitor and Four Strip-Line Electrodes for Hls II Injector* 3587
SUSPSNE076   use link to see paper's listing under its alternate paper code  
 
  • K. Tang, J. Liu, P. Lu, Q. Luo, B.G. Sun, H. Xu, J. Xu, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  In order to nondestructively measure the beam energy spread with a beam energy of 0.8GeV in the injector at the upgrade project of Hefei Light Source (HLS II) in real time, a beam energy spread monitor (BESM) using beam position monitor (BPM) with four stripline electrodes has been developed. And a screen monitor (SM) near the BESM is used to measure beam energy spread destructively. This paper introduces in brief the beam position measurement system and beam transverse profile measurement system. The relationship between the transverse size at the BESM and at the SM (Flag3) is discussed in detail in this report. The result shows that energy spread measuring result of BESM and SM is 0.19% and 0.18% respectively. So we can draw a conclusion that the BESM is capable of nondestructively measuring the beam energy spread.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME143  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME144 Stripline Beam Position Monitor for THz Source Based FEL 3590
 
  • J. Xu, L. Li, J. Liu, P. Lu, Y.J. Pei, B.G. Sun, K. Tang, J.G. Wang, F.F. Wu, H. Xu, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A 14MeV Linac with both the micro-pulse repetition rate 2856MHz and the macro-pulse width 6us for the THz Source Based FEL was proposed. In order to measure the beam position, a stripline beam position monitor (BPM) was designed, and a commercial BPM electronics Libera Brilliance Single Pass was adopted. As the input carrier frequency of the BPM electrode signal is 2856MHz, but the operating frequency of the Libera Brilliance Single Pass is 500MHz, so a front-end electronics was needed before the electrode signals feed into Libera Brilliance Single Pass. The front-end electronics was designed to make the BPM electrode signals of 2856MHz convert to 500MHz.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME144  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)