THPME140 New Beam Diagnostics and Related Study on HLS Photo-Injector and HLS II 3578
 
  • Q. Luo, H.T. Li, P. Lu, B.G. Sun, K. Tang, J.J. Zheng, Z.R. Zhou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  Funding: Work supported by Natural Science Foundation of China 11005105, 11005106, 11205156 and 11375178.
A team in NSRL is now doing research about small model accelerators and carrying out series of related experiments on HLS photo-injector and HLS II storage ring. Cavity beam multi-parameter monitor system designed for the HLS photocathode RF electron gun consists of a beam position monitor, a beam quadrupole moment monitor and a beam density and bunch length monitor. TM0n0 modes of cavity can be used to work out beam density and bunch length simultaneously. Miniaturization of FEL facilities is now being studied based on results of experiments and theoretical work before. The team also participate in commissioning of HLS II, i.e. measured work points of the new storage ring and did some research on longitudinal bunch-by-bunch feedback system.
 
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME140  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME141 Design of Beam Intensity Measurement System in Injector for HLS II 3581
 
  • C. Cheng, P. Lu, B.G. Sun, K. Tang, J. Xu, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  A new beam intensity measurement (BIM) system has been developed and has been used in the upgrade project of HLS II. After the upgrading is accomplished, electron energy in Injector endpoint will increase from 200MeV to 800MeV to achieve the goal of top-off injector. Meanwhile, macro pulse width changes from 1us to 1ns and peak intensity from 50mA to 1A approximately. So three fast current transformers (FCTs) and two integrating current transformer (ICTs) are installed in Linac and Transport Line to measure single pass beam parameters. In this article, off-line calibration of beam transformer is elaborated. Since the fast pulse signals from beam transformer will be hugely distorted after they transmit from Injector vacuum chamber to the Injector beam diagnostic centre room after hundreds of meters long LMR-400 cable, signal recovery algorithm based on FFT/IFFT is used to re-appear the true original signal and calculate the calibration efficient. In the end, resolution and measurement result of the BIM system is presented.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME141  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
THPME143 Measuring Energy Spread Using Beam Screen Monitor and Four Strip-Line Electrodes for Hls II Injector* 3587
SUSPSNE076   use link to see paper's listing under its alternate paper code  
 
  • K. Tang, J. Liu, P. Lu, Q. Luo, B.G. Sun, H. Xu, J. Xu, Y.L. Yang, Z.R. Zhou, J.Y. Zou
    USTC/NSRL, Hefei, Anhui, People's Republic of China
 
  In order to nondestructively measure the beam energy spread with a beam energy of 0.8GeV in the injector at the upgrade project of Hefei Light Source (HLS II) in real time, a beam energy spread monitor (BESM) using beam position monitor (BPM) with four stripline electrodes has been developed. And a screen monitor (SM) near the BESM is used to measure beam energy spread destructively. This paper introduces in brief the beam position measurement system and beam transverse profile measurement system. The relationship between the transverse size at the BESM and at the SM (Flag3) is discussed in detail in this report. The result shows that energy spread measuring result of BESM and SM is 0.19% and 0.18% respectively. So we can draw a conclusion that the BESM is capable of nondestructively measuring the beam energy spread.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-THPME143  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)