Author: Yu, Y.T.
Paper Title Page
TUPRO109 Calculation of Heat Load on Double Mini-beta Y Undulators 1304
 
  • J.C. Huang, T.Y. Chung, C.-S. Hwang, Y.T. Yu
    NSRRC, Hsinchu, Taiwan
 
  Two collinear in-vacuum undulators (IU22) are adopted for light source of X-ray coherence beamline in Taiwan photon source. Each undulator is 3 meter and the drift space between two undulator is 3.991m. The synchrotron radiation is propagating in the longitudinal direction and will result in a serious heat load problem for undualtor downstream. The magnet array of undualtor downstream will received the synchrotron radiation of 142W from upstream bending magnet and undualtor. Heat load is a critical challenge for in-vacuum undulator in double mini-beta Y lattice and therefore details analysis in this paper.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-TUPRO109  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
TUPRO111 Summary of Field Quality of TPS Lattice Magnets 1310
 
  • J.C. Jan, C.-H. Chang, Y.L. Chu, T.Y. Chung, C.-S. Hwang, C.Y. Kuo, F.-Y. Lin, Y.T. Yu
    NSRRC, Hsinchu, Taiwan
 
  A modern 3-GeV synchrotron radiation light source is under construction in NSRRC, named Taiwan Photon Source (TPS). Great quality of magnets is required to control the electron-beam in the required orbit in the storage ring (SR) and the booster ring (BR) of TPS. The mechanical and magnet field performance of these magnets were fully inspected in NSRRC. The standard deviation of the integral field strength of 48 SR-dipole magnets is better than 0.1%. The integral multipoles and offsets of the magnetic center of the 240 SR quadrupole and 168 SR sextupole magnets conform to strict specifications. The field characteristics of the BR combined-function dipole magnet were analyzed with an average of processing raw data. The standard deviation of the field strength of 54 BR dipole-magnets is better than 0.2%. The field quality of 36 BR pure quadrupole and 48 BR combined-function quadrupole magnets are accepted to meet the requirement of the booster ring. The field strength and multipole errors of 24 BR sextupole magnets were also examined. The detailed magnetic performance and technical issues of lattice magnets are discussed in this report.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-TUPRO111  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)