Author: Lotz, M.
Paper Title Page
WEPME029 Development of a Field Emitter-based Extractor Gauge for the Operation in Cryogenic Vacuum Environments 2320
 
  • M. Lotz, O.K. Kester, St. Wilfert
    GSI, Darmstadt, Germany
 
  This paper presents an investigation of a CNT emitter-based extractor gauge which is designed for pressure reading in cryogenic ultra-high vacuum systems. The results show that the modified gauge works well in both room temperature and cryogenic vacuum environments. Furthermore, it could be demonstrated that the modified gauge responds much more sensitive to small pressure fluctuations in cryogenic environments than the same gauge type having a hot-filament cathode.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-IPAC2014-WEPME029  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)