MOPEB042 Towards a Consolidation of LHC Superconducting Splices for 7 TeV Operation 367
 
  • F.F. Bertinelli, N. Catalan-Lasheras, P. Fessia, C. Garion, S.J. Mathot, A. Perin, C.E. Scheuerlein, S. Sgobba, H.H.J. Ten Kate, J.Ph. G. L. Tock, A.P. Verweij, G.P. Willering
    CERN, Geneva
 
 

Following the analysis of the September 2008 LHC incident, the assembly process and the quality assurance of the main 13 kA interconnection splices were improved, with new measurement and diagnostics methods introduced. During the 2008-2009 shutdown ~5% of these 10 000 splices were newly assembled with these improvements implemented, but essentially maintaining the original design. It is known today that a limiting factor towards 7 TeV operation is the normal conducting resistance of ~15% of the original main 13 kA interconnection splices, associated to the electrical continuity of the copper stabiliser. A "Splices Task Force" has been set up at CERN to evaluate the need for, develop and test design improvements and prepare the implementation of a consolidation campaign. Important issues of splice design, process choice, resources and time requirements are considered.

 
MOPEB076 Mobile CT-System for In-situ Inspection in the LHC at CERN 447
 
  • L.R. Williams, F. Caspers, J.M. Dalin, J.Ph. G. L. Tock
    CERN, Geneva
  • V. Haemmerle, C. Sauerwein, I. Tiseanu
    RAYSCAN, Meersburg
 
 

For the inspection of certain critical elements of the LHC machine a mobile computed tomography system has been developed and built. This instrument has to satisfy stringent space, volume and weight requirements in order to be usable and transportable to any interconnection location in the LHC tunnel. Particular regions of interest in the interconnection zones between adjacent magnets are the plug in modules (PIM), the soldered splices in the superconducting bus-bars and the interior of the quench diode container. This system permits detailed inspection of these regions without needing to break the cryo vacuum. Limited access for the x-ray tube and the detector required the development of a special type of partial tomography, together with suitable reconstruction techniques for 3 D volume generation from radiographic projections. We present the layout of the complete machine and the limited angle tomography as well as a number of radiographic and tomographic inspection results.