WEPEC066 Latest Results and Test Plans from the 100 mA Cornell ERL Injector SCRF Cryomodule 3043
 
  • M. Liepe, S.A. Belomestnykh, E.P. Chojnacki, Z.A. Conway, G.H. Hoffstaetter, R.P.K. Kaplan, S.E. Posen, P. Quigley, J. Sears, V.D. Shemelin, V. Veshcherevich
    CLASSE, Ithaca, New York
 
 

Cornell University has developed and fabricated a SCRF injector cryomodule for the acceleration of a high current, low emittance beam in the Cornell ERL injector prototype. This cryomodule is based on superconducting rf technology with five 2-cell rf cavities operated in the cw mode, supporting beam currents of up to 100 mA. After a rework of this cryomodule in 2009 to implement several improvements, it is now in beam operation again. In this paper we report on latest results and discuss future test plans.