A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Sawabe., M.

Paper Title Page
WEPEC027 Long-period Monitoring of Electro-polishing Electrolyte in EP Facility at KEK 2947
 
  • M. Sawabe., H. Hayano, S. Kato, M. Nishiwaki, T. Saeki
    KEK, Ibaraki
  • P.V. Tyagi
    Sokendai, Ibaraki
 
 

We have constructed an Electro-polishing (EP) Facility in the Superconducting RF Test Facility (STF) at KEK in 2008. The EP facility has been used for the EP process of Superconducting RF (SRF) 9-cell cavities for more than one year. In the EP facility, the capacity of the EP-electrolyte reservoir tank is 2,000 L. This size is relatively large if compared with EP facilities in other laboratories. It means that the quality control of EP electrolyte is more difficult because the status of EP-electrolyte changes as the aging of EP-electrolyte proceeds. In the real EP-process operations, we circulated the EP electrolyte of 1,100 L which was firstly delivered into the tank in January 2008 and was disposed in May 2009. During this period, we performed the EP processes 40 times and periodically measured the concentration of Nb ,Al ,HF in the EP electrolyte. In this article, we report the detailed results of the EP-electrolyte monitoring as well as the observation of changing electronic current oscillation in the EP processes during this period in the EP facility at STF/KEK.