WEPEB027 Preliminary Operational Experiences of a Bunch-by-bunch Transverse Feedback System at the Australian Synchrotron 2743
 
  • D.J. Peake, R.P. Rassool
    Melbourne
  • M.J. Boland, R.T. Dowd, Y.E. Tan
    ASCo, Clayton, Victoria
 
 

The Australian Synchrotron storage ring has a resistive wall instability in the vertical plane. Presently this instability is being controlled by increasing the vertical chromaticity. However new in-vacuum insertion devices that significantly increase the ring impedance may demand chromatic corrections beyond the capabilities of the sextupole magnets. A transverse bunch-by-bunch feedback system has been commissioned to combat the vertical instability* and provide beam diagnostics**. A high frequency narrow band mode that could not be damped was initial encountered with IVUs at minimum gap preventing the system from being implemented during user beam. Tuning of the bunch fill pattern, the digital filters and mapping out the system response lead to a configuration for user mode operations.


* Spencer, M.J. et. al. EPAC'08, Genoa, Italy
** Peake, D.J. et. al. PAC'09, Vancouver, Cananda