MOPD029 Development of a new Broadband Accelerating System for the SIS18 Upgrade at GSI 744
 
  • P. Hülsmann, R. Balss, H. Klingbeil, U. Laier, K.-P. Ningel, C. Thielmann, B. Zipfel
    GSI, Darmstadt
 
 

This paper describes the development of a new rf accelerating cavity based on novel magnetic alloy materials (MA-materials) for operation at harmonic number h=2 (f=0,43- to 2,8 MHz) to provide the necessary accelerating voltage for SIS18 injector operation with high intensity heavy ion beams in a fast operation mode with three cycles per second. The acceleration system consist of three units which are able to operate independently from each other. That is important, since each ion for FAIR has to cross the h=2-rf-system and in the case of a damage a reduced operation has to be ensured. Since the cavities are filled with lossy MA-ring-cores, which are iron based Finemet FT3M ring cores from Hitachi, the cavities show a broadband behaviour and thus no cavity tuning during the acceleration ramp will be necessary. Due to the high saturation field strength of Finemet (1,2 T) the overall length of all three cavity units can be very short. This is an important feature since due to many insertions which were additionally inserted into the synchrotron ring SIS12/18 in the meantime, the available length in SIS12/18 for the cavity units is with 4 m very short.

 
TUPEA037 Dual Harmonic Operation at SIS18 1410
 
  • K.-P. Ningel, P. Hülsmann, H. Klingbeil, U. Laier, C. Thielmann, B. Zipfel
    GSI, Darmstadt
 
 

The heavy ion synchrotron SIS18 at the GSI facility will be upgraded by a dual harmonic RF acceleration system in the process of using SIS18 as booster for the future FAIR SIS100 accelerator. The dual harmonic mode will extend the SIS18 operating towards higher beam currents. As a part of a large LLRF upgrade at the synchrotron RF systems at GSI, new FPGA and DSP based electronics have been designed, built and commissioned. To prove the functionality of the LLRF equipment as well as the general dual harmonic topology, machine development experiments using the existing cavities have been performed. During these experiments, the main parameters of the control loop were determined. Additionally, the impact of RF gap voltage amplitude and phase variations onto the ion beam have been investigated, like e.g. creation of a dual harmonic bucket or fast changes in harmonic number. The experiments showed a high sensitivity of the ion beam to small deviations in the phase between both harmonics and thereby confirmed the requirements on the high precision regarding phase accuracy of the electronic setup especially for the closed loop phase control systems.