TUPEC031 The Operation of Injection System in the SSRF 1788
 
  • M. Gu, Z.H. Chen, B. Liu, L. Ouyang, R. Wang, Y. Wu, Q. Yuan
    SINAP, Shanghai
 
 

The injection system composed of four kickers and two septa in the SSRF have been built and operated. The commissioning shows that fine injecting efficiency and smaller disturbance are carried out. The septum magnets are eddy current designs with a sheet of magnetic screening material around the stored electron beam to reduce the leakage field. The beam tube with RF finger flanges at each end is added to keep the continuity of impedance for the circulating beam. The pulser excite the septum with 60μsecond waveform of half sine-wave and 8kA peak current. Four identical kicker magnets provide the symmetric bump in 10 meter long straight sections. The excitation waveform is a 3.8μsecond half sine pulse up to 7 kA peak. The emphasis was on achieving the best possible tracking in time of the magnet field waveforms so that the residual closed orbit disturbance is minimized for top-up injection. The performance of the injection system with these pulsed magnets are described.

 
WEPD034 In-Vacuum Undulator Controller Design for SSRF 3168
 
  • M. Gu, R. Chen, Z.H. Chen, G.-Y. Jiang, R. Wang, Q. Yuan
    SINAP, Shanghai
 
 

The undulator controller based on Siemens S7-300 PLC is mainly consisted of controlling motion of two stepper motor, monitoring real-time gap position of upstream and downstream through position feedback derived from four linear absolute encoders (LAEs) with 0.1μm resolution, monitoring cooling water's temperature and flux (CWTF), monitoring magnet array temperature (MAT), providing remote access for EPICS via Ethernet, as well as MPS and PPS interlock interface to and from upper-level protection system. In addition, the controller is equipped with considerate motion safety protection tactics. As for the gap position protection, besides mechanical hard stop, software limit, photo-interrupter limit and kill switch are available to achieve it. As for the taper protection, software limit is available to achieve it.