A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z  

Biswas, B.

Paper Title Page
TUPEC005 Development and Commissioning of the CUTE-FEL Injector 1716
 
  • S. Lal, B. Biswas, S. Chouksey, S.K. Gupta, U. Kale, M. Khursheed, A. Kumar, V. Kumar, P. Nerpagar, K.K. Pant, A. Patel, V. Prasad, A.K. Sarkar
    RRCAT, Indore (M.P.)
  • S. Krishnagopal
    BARC, Mumbai
 
 

The injector system for the Compact Ultrafast Terahertz Free Electron Laser (CUTE-FEL) consists of a 1 ns, 90 kV pulsed thermionic electron gun, a 476 MHz sub-harmonic prebuncher, and a standing wave, S-band Plane Wave Transformer (PWT) linac capable of accelerating beam to 10 MeV. Beam from this injector will be transported to the entrance of the undulator through a beam transport line, with the required diagnostic elements, that has been designed, developed and commissioned. The control system and the low and high power microwave lines have also been commissioned. In this paper, we discuss salient features of the injector system and results from recent commissioning trials of the injector.